What should I do if the wall-hung boiler has insufficient pressure? 10 days of solutions to popular problems
Recently, insufficient pressure in wall-hung boilers has become a hot topic during the heating season, with many users asking for help on social platforms and home forums for related issues. This article will provide you with structured solutions based on hot discussions across the Internet in the past 10 days.
1. Common symptoms of insufficient pressure in wall-hung boilers

| Symptoms | Frequency of occurrence (discussions in the past 10 days) |
|---|---|
| Decreased heating effect | 1,200+ times |
| Frequent error codes | 980+ times |
| Hot water discharge is unstable | 750+ times |
| Abnormal equipment noise | 520+ times |
2. Analysis of the main reasons for insufficient pressure
| Reason type | Proportion (based on maintenance data) | Typical characteristics |
|---|---|---|
| System leaks | 42% | pressure continues to drop |
| Automatic exhaust valve failure | 28% | Significant pressure fluctuations |
| Expansion tank failure | 18% | The pressure gauge jumps violently |
| Insufficient initial water injection | 12% | New equipment issues |
3. Step-by-step solution
Step 1: Pressure Test
Check the pressure gauge value, the normal range should be 1-1.5bar. Below 0.8bar needs to be dealt with immediately.
Step 2: Simple pressure compensation operation
| Operation process | Things to note |
|---|---|
| 1. Turn off the power supply to the wall-hung boiler | Be sure to operate in a cold state |
| 2. Find the refill valve (usually located at the bottom) | |
| 3. Rotate 90 degrees counterclockwise to start filling the water | |
| 4. Observe the pressure gauge to 1.2bar | No more than 2bar allowed |
Step 3: Check for leaks
If the pressure drops by more than 0.3bar within 24 hours after pressure replenishment, key inspections are required:
- Radiator interface
- Pipe connection parts
- Bottom of wall-hung boiler
4. Q&A on recent high-frequency user issues
| question | solution |
|---|---|
| Immediately after replenishing the pressure, the alarm will sound again | Check the air pressure of the expansion tank (should be maintained at 0.8-1bar) |
| Can't find the location of the water replenishment valve | Refer to the diagram in the instruction manual. Most valve brands have a "+" mark. |
| Pressure gauge pointer does not move | It may be that the pressure sensor is faulty and requires professional maintenance. |
5. Professional maintenance suggestions
It is recommended to contact after-sales service when the following situations occur:
1. Need to replenish pressure more than 2 times a week
2. Found obvious leakage points
3. The equipment is accompanied by abnormal alarm sounds.
4. The pressure gauge shows more than 2.5bar
6. Preventive maintenance guide
| maintenance items | cycle | Operational points |
|---|---|---|
| System pressure check | monthly | Record pressure trends |
| Expansion tank detection | Before heating every year | Use a tire pressure gauge to measure pre-inflation pressure |
| Pipe tightness inspection | every two years | Focus on checking aging and corrosion |
With the above structured solutions, 90% of the problem of insufficient pressure can be solved by yourself. It is recommended that users save this guide for emergencies and contact professional service personnel in time in case of complicated situations.